Главная страница Новости Гостевая книга Главная bs0dd.net Телефоны Список моделейПрошивки Net Monitor Активация FT/NMNet Monitor (DCT3) Net Monitor (DCT4) Софт и игры Java МИДлетыОфициальное ПО Софт для 5510 Программы для ПК Подключение Дата-КабелиFLOSYS FBUS/MBUS доки DLR-3 MBUS (atrox) Моддинг Цветной дисплей (6310)WAP WAP-шлюзWAP-страница Другое Архив Nokia 9210Электроника МК Kannel для Windows |
SCHEMATICS FOR DAU-9P (MBUS)There is two
versions, version to work with I.C. MAX3232, that it's not easy to find
and version with MAX232. Both versions works for Nokia Data Suite (DAU-9P)
and Wintesla (M2Bus).
All interface is powered by RTS and DTR signals. D1 and D2 is recommended in Shottky design since lower dropout. The voltage regulation (which should be 3.3V) is here done by 5V regulator with diodes D3 - D5 on which is drop about 1.8V, so final voltage is 3.2V, on diode is drop about 0.6V, so before regulator it may be 4.4V, after regulator about 4.1V, drop on D3 - D5 diodes is about 1.8V and in this case voltage can be 2.3V) - it can be wrong (I tested MAX3232 works fine on voltage 2.0V), but amperage of COM port will be unnecessarily bigger. Zener diodes DZ1 and DZ2 are VERY important to safety of Your phone. Normally are values of log. 1 about 3.3V and little overcross of this value can damage the phone – so power blast at turning on computer or connecting interface into computer. DZ1 and DZ2 diodes cuts-down this voltage to 2.7V - it is enough to log. 1 and it is hardly under maximal voltage value. In all, it is standard wiring of MAX232. Pins No.8 (R2IN) and No.9 (T2IN) You needn't to connect to ground. If you use a MAX232 is necesary use a 1k ressistor to reduce voltage at PIN 10 from I.C. so we guaratee a correct voltage at Tx for the phone and it's not necesary 4007 diodes because Max232 work at 5V. To use MBus interface we need only add a 4148 diode between RX and TX and get a new cable from TX to connect it to PIN 6 in phone connector. To get phone connector use a handsfree portatil (not nokia original, because it's too expensive) and cut connector. Be sure that it's not thermo-sealed and it uses all pins. I recommend you
to use Max3232 version, because using Max232 comunication with phone using
FBUS (Data Suite) sometimes may be failed.
Component list:Phone Connector pinout
!!!ВНИМАНИЕ!!!: DAU-9P получает питание с порта RS-232 и требует как минимум 7,7 V для работы микросхемы.
Это условие не соблюдается в большинстве Ноутбуков и USB-COM контроллеров, уровни сигнала в которых обычнно равны 5,5 - 6,5 V, поэтому DAU-9P может не работать!
|