Test 36 - Software Reset Statistics

Available in: 2100, 3330, 5110, 6150, 6210, 7110, 8210, 8250

This test shows the history of the reset reasons described in “Test 35 – Reason for Last Software Reset”.

Test screen Help screen
Test 36 Test 36 Help Test 36 (9210i) Help

UN: Number of unknown resets.

WD: Number of resets due to hardware watchdog.

DSP: Number of resets due to DSP recovery reset.

SIM: Number of resets due to SIM related errors.

IDL: Number of resets due idle task not running.

STK: Number of resets due to stack overflow.

These counters are saved in the EEPROM and are not reset on reboot. There is no test to reset them, not even “Test 240 – Reset all”. The only way is with service software or by modifying the EEPROM contents.