Nokia DCT3 Net Monitor - activation

Net Monitor
Activation of the engineering menu "Net Monitor" on DCT3 (3210, 3310, 6210, 7110 and etc.) platform phones



The DCT3 platform includes the following models:
NK402 NK503 NK702 2100 2190 3210 3210e 3210i 3260
3285 3310 3310e 3315 3320 3330 3350 3360 3390
3395 3410 3610 3810 5110 5110i 5120 5125 5148
5160 5165 5170 5180 5185 5190 5210 5510 6110
6130 6138 6150 6150e 6161 6162 6185 6188 6190
6200 6210 6210e 6250 6290 7110 7190 7290 8210
8250 8270 8290 8810 8850 8855 8890 9000 9000i
9110 9110i

Also, this activation method is suitable for 9210/9210i/9290, although they refer to a separate platform DCTL, their telephone parts (CMT) are compatible with DCT3.

1. Connecting to a computer

Connection to a computer can be made using COM cable or IR port. The IrDA option is simpler, but not all models with it support "Net Monitor" activation via IrDA. These phones require a cable. Business models (6xxx and some 5xxx/7xxx) are officially designed for cable connection and have a connector brought out to the outside. They are compatible with DAU-9(P) (6110/6150/5110) and DLR-3(P) (6210/6250/7110) cables. For more recent models, you can also use the old DAU-9(P), which is not officially supported. For models of other segments that are not officially intended for connection to a PC (but such a possibility exists), you must use unofficial MBUS / FBUS cables. They are inserted into the battery compartment and the spring-loaded contacts rest against the pads on the phone's board.

Picture 1 Picture 2


2. Installation of special soft

To activate the menu, you need the appropriate software, such as LogoManager (recommended) or Oxygen Phone Manager. Both programs can be downloaded from the "PC software" tab. Installation is simple and straightforward.

Picture 1 Picture 2


3. Menu activation

After establishing a connection with the phone, depending on the program:
  • LogoManager: menu "Tools" -> "Network Monitor...", in the appeared window of outputs, click "Enable...", depending on the desire, select the "Field Test" mode (basic network tests 1-19) or "Engineering" (full set of tests), press "OK"
  • OPM: menu "Phone" -> "Network Monitor", select "Activate" to activate the "Engineering" mode (the "Field Test" mode cannot be activated in OPM)

Picture 1 Picture 2


4. PROFIT!!!

After activation, the phone will reboot and the item "Net Monitor" of interest to us will appear as the last item in the main menu. This completes the activation process!
For details on using "Net Monitor" see the online description on the Net Monitor (DCT3) tab. There are also links to some third-party documents, used in the preparation of this description.

Picture 1 Picture 2


WAP-gateway IP: 79.186.227.103
Port: 9201

Русский
Powered by COMPPAG 0.50
2022-2024 © Compys S&N Systems